Skip to content
MB Datasuite
  • Features
  • Applications
  • Energy
  • Visualization
  • Prices
  • Free Trial
  • Deutsch
MB Datasuite
  • Features
  • Applications
  • Energy
  • Visualization
  • Prices
  • Free Trial
  • Deutsch

System requirements and compatibility

5
  • System requirements and secure operation
  • Operate as a windows service
  • Database connections 
  • PLC support  
  • White Label

Quick start

9
  • Installation  
  • Set up PLC connection  
  • Create trigger  
  • Select trigger variable in the handshake  
  • Execute trigger  
  • Create Excel file  
  • Write header data to the file  
  • Write record  
  • Connect to a Database

Tutorials, HowTos and instructions

1
  • Alarm emails with OPC-UA: Monitoring excess temperature with an S7 1500 PLC

User Manual

96
  • General information on the user manual
  • Licensing
    • Determining the required licence  
    • Activate your licence  
  • Settings
    • General information
    • Export  
    • Import  
    • Password protection  
    • Change language  
    • Factory settings  
  • Trigger
    • General information about the trigger
    • Create trigger  
    • Trigger structure  
    • Use variables  
    • Additional trigger editing functions
      • Calculations and Formatting of SPS Data
      • Invert Excel Actions 
      • Changing data blocks for all variables in the trigger 
    • Trigger Actions
      • General information
      • Write variable 
      • Excel – Writing  
      • Excel – Read  
      • Convert Excel file to PDF  
      • Print Excel file  
      • Convert Excel file to HTML file  
      • Database: Execute Query 
      • Database: Write record (Insert) 
      • Database: Write several data records (insert) 
      • Database: Read data record (Select) 
      • Database: Read multiple records (Select) 
      • File options (copy, move, rename, delete)  
      • Read out file names in folder  
      • Execute REST Request 
      • FTP Upload
      • Send e-mail  
      • Send SMS  
      • Send message using Telegram 
      • Send message using Threema  
      • Start external applications  
      • Exporting and importing data blocks (DB)
      • Update Data Block
      • Set PLC time 
    • Trigger trigger conditions and handshake
      • General information on Trigger conditions and handshake  
      • Standard handshake  
      • Individual handshake  
    • Error handling and log
      • Error handling and log  
  • Accounts
    • Telegram account
      • Telegram time limit
      • Configure Telegram account 
      • Set up Telegram
    • Threema account
      • Threema Time limit  
      • Configure Threema account 
      • Set up a Threema account
    • E-Mail account
      • Email time limit
      • Configure email account  
      • General info about e-mail account
    • SMS-account
      • Configuring a SMS / Seven Account
      • SMS time limit
      • SMS Sandbox
  • Error Codes
    • General   (0 – 99)
    • PLC (200 – 299)
    • E-mail (300 – 399)
    • SMS (400 – 499)
    • Excel (500 – 599)
    • OPC UA (700 – 799)
    • Databases (800 – 899)
    • Print (1000 – 1099)
    • PDF (1100 – 1199)
    • HTML (1200 – 1299)
    • Start external applications  (1300 – 1399)
    • Rest (1400 – 1499)
    • Time Master (1900 – 1999)
    • Telegram (2000 – 2099)
    • Threema (2100 – 2199)
  • Devices (Shelly)
    • General information about Shelly
    • Add devices 
    • Using Shelly variables 
  • Excel, CSV, PDF files
    • CSV files: Formats, special characters, encodings
    • General information on Excel files
    • File selection 
    • File formats  
    • Read Access 
    • Write Access 
  • Control systems (PLC connections)
    • General information on PLC connections
    • Create PLC connection  
    • Variables  
    • Configure PLC connection  
  • Databases
    • General information on databases
    • Database: Write record (Insert) 
    • Database: Write several data records (insert) 
    • Database: Read data record (Select) 
    • Database: Read multiple records (Select) 
    • Database: Execute Query 
  • Webserver / REST API
    • General information web server/rest API
    • Settings and security 
    • Calling up web pages 
    • Use Rest-API 
  • Support
    • Create Support Packages  
    • Support contact details

Upgrade from version 2 to version 3

1
  • Change from version 2 to version 3  
  • Home
  • Docs
  • System requirements and compatibility
View Categories

System requirements and secure operation

Lesedauer: 2 min

What are the system requirements for DataSuite? #

To ensure stable and high-performance operation of the DataSuite, the following system requirements regarding hardware and operating system must be met:

ComponentRecommendation
ProcessorDual-core, 4 cores or more recommended
RAMAt least 4 GB, 8–16 GB recommended
StorageSSD recommended
Operating SystemWindows 10, 11 or Server 2016–2022

Note: These DataSuite system requirements are minimum values. In more complex scenarios, such as with multiple controllers, triggers, or large volumes of data, a more powerful setup is recommended.


Which Windows versions are supported by DataSuite? #

DataSuite supports all modern Windows versions starting from Windows 10 (64-bit):

  • Windows 10 and 11
  • Windows Server 2016, 2019, and 2022

Not supported:

  • DataSuite does not support Linux operating systems.
  • Windows on ARM processors is officially not supported.

Can DataSuite be used on virtual machines (VMs)? #

Yes, DataSuite can be installed on virtual machines such as VMware or Hyper-V.
However, caution is advised when using code-based licenses: Changes to the VM’s hardware configuration may invalidate the license. For such setups, we recommend using the floating license (USB dongle) together with a USB dongle server, e.g., the SEH myUTN-50a.


Secure operation of DataSuite #

Beyond the technical system requirements, secure and stable deployment of DataSuite in production environments is crucial.

IT security when using DataSuite #

  • Keep Windows and all installed software up to date
  • Enable and maintain a firewall and antivirus protection
  • Avoid unprotected internet access, especially when using e-mail, SMS, or Telegram notifications

Network separation: Isolate machine and corporate networks #

In industrial environments, we recommend using a PC with two Ethernet interfaces, such as Eth0 for the machine network and Eth1 for the corporate network. This allows a clear network separation between production and IT infrastructure.

Both networks should use different IP address ranges to minimize risks and ensure stable communication with controllers, especially with direct PLC connections or OPC UA communication.

Implementation of this setup should be planned in cooperation with your IT department or system integrator. Depending on your IT strategy, using VLANs may also be advisable.


Availability and fail-safety #

  • Use industry-grade PC hardware
  • Install an uninterruptible power supply (UPS)
  • Use high-quality network cables and switches
  • Optionally run DataSuite on a centrally managed VM in your data center

Wie findest du den Beitrag?
Immer noch Fragen? Wie können wir helfen?

Wie können wir helfen?

Inhalt
  • What are the system requirements for DataSuite?
  • Which Windows versions are supported by DataSuite?
  • Can DataSuite be used on virtual machines (VMs)?
  • Secure operation of DataSuite
    • IT security when using DataSuite
    • Network separation: Isolate machine and corporate networks
    • Availability and fail-safety

MB DataSuite

  • Home
  • Features
  • Applications
  • Prices

Info portal

  • Knowledge Base
  • Newsletter
  • Change Log
  • FAQ & Support

Company

  • About us
  • Imprint
  • Linkedin
  • YouTube
  • Facebook

Legal

  • Privacy
  • EULA
  • Cookie Settings

Help and support

  • Tel +49 2742 72927 80
  • Live Presentation
  • Contact
  • Deutsch
    • About us
    • Support & FAQ
    • Contact
    • Imprint
    • TOS and EULA
    • Privacy policy
    • Linkedin
    • Facebook
    • Youtube
    [MB] Software und Systeme GmbH