Go to “PLCs”. There you will find the [MB] simulator for testing. If you want to set up a real PLC connection, you can do this via the “Create new PLC” button in one of the groups.
Now you get a selection of which type of controller you want to use
The DataSuite supports Siemens Put/Get and OPC-UA. If you are using a Siemens device with OPC-UA server, there is an additional option that makes it easier to find and import data blocks.
On this page you can configure the connection to your PLC when using OPC-UA. Set the IP, Port and Security Policys for this.
On this page you can configure the connection to your PLC when using Put/Get. Set the IP, rack and slot for this. For the 1200 and 1500 controllers, access must first be enabled (Configure PLC connection).
Variables can be imported from Tia Portal (Variables). Two test data modules are already created. If a real PLC is used, the modules should be adapted or deleted.